한국어

소프트스위치

온누리070 플레이스토어 다운로드
    acrobits softphone
     온누리 070 카카오 프러스 친구추가온누리 070 카카오 프러스 친구추가친추
     카카오톡 채팅 상담 카카오톡 채팅 상담카톡
    
     라인상담
     라인으로 공유

     페북공유

   ◎위챗 : speedseoul


  
     PAYPAL
     
     PRICE
     

pixel.gif

    before pay call 0088 from app


OpenSIPS Control Panel and Homer integration

https://blog.opensips.org/2017/08/02/opensips-control-panel-and-homer-integration/

imgpsh_fullsizeThere are several articles and examples showing how to integrate Homer and OpenSIPS for SIP tracing/capturing purposes – capturing SIP, log, REST queries, network data, Management commands and more. This is an integration at data exchange level.

But an integration is also possible at the Web portal level – to integrate the Homer portal into the OpenSIPS Control Panel, the OpenSIPS provisioning interface.

Why? To get fast control over your whole system, with a single login. Why login and check two web interfaces, when you can have only one.

The OpenSIPS Control Panel 7.2.3, matching OpenSIPS 2.3, can integrate the Homer portal as an internal tool.

CP_Homer_dashboard

Nice, isn’t it?

The integration is done with full security consideration (the two web portals are performing cross authentication via REST APIs) and with no loss in functionality.

So, how can you can set this up?

OpenSIPS Control Panel configuration

First, be sure you have the Homer tool enabled in your OpenSIPS Control Panel installation. In the config/modules.inc.php file, in the $config_modules array, in the “system” section, for the “homer” entry, be sure you have set “enabled” => true.

After that, you need to configure the Homer tool, to be able to talk to the Homer portal. In the config/tools/system/homer/local.inc.php file you need to set a couple of options:

  • $homer_URL – this is the HTTP URL pointing the Homer portal
  • $homer_auth_method – the authentication method against Homer; the easiest and most flexible is the “get” method.

Homer configuration

For Homer, all the changes to be done are in the api/preferences.php file.

First of all, switch the authentication engine from “Internal” (via passwords) to “External” (via API):

define(‘AUTHENTICATION’,”External”);

Then configure the External Authentication engine as follows:

/*********[EXTERNAL AUTH ]********/
define(‘EXTERNAL_AUTH_URI’, “http://10.0.0.10/cp/tools/system/homer/auth.php”);
define(‘EXTERNAL_AUTH_METHOD’, “GET”);
define(‘EXTERNAL_AUTH_PARAM’, “param=KEY”);
define(‘EXTERNAL_AUTH_REQUEST_TYPE’, “get”);
define(‘EXTERNAL_AUTH_REQUEST_KEY’, “externalid”);
define(‘EXTERNAL_AUTH_POSITIVE_REPLY’, “200”);
define(‘EXTERNAL_AUTH_REPLY_USER_INFO’, “json”);

The only custom option is the EXTERNAL_AUTH_URI which is an HTTP URL pointing back to your OpenSIPS Control Panel installation – this must be constructed as

http://OCP_HOST/OCP_PATH/tools/system/homer/auth.php

where http://OCP_HOST/OCP_PATH is the HTTP URL you normally use to access your OpenSIPS Control Panel login page.

And you are done!

Note that you will not be able to login anymore into Homer portal via username and password.

Results

The result is a handy way to check CDRs, ongoing dialog, traces, everything, under the same umbrella.

CP_Homer_callflow

Even more, if the Homer tool is present, the CDRviewer tool in OpenSIPS Control Panel (for listing the CDRs) will automatically generate a link from the SIP call-ID value of the CDR to the call flow in Homer – with a single click you can view the call flow for a given CDR.

CP_Homer_cdrviewer.png

Enjoy it!

 

조회 수 :
43667
등록일 :
2017.08.17
10:07:43 (*.160.88.18)
엮인글 :
http://webs.co.kr/index.php?document_srl=3310654&act=trackback&key=cf8
게시글 주소 :
http://webs.co.kr/index.php?document_srl=3310654
List of Articles
번호 제목 글쓴이 조회 수 추천 수sort 날짜
112 Opensips sip capture re designed admin 21903   2017-07-16
 
111 WebRTC with OpenSIPS WebSocket is a protocol provides full-duplex admin 33669   2015-04-04
 
110 WebSocket Support in OpenSIPS 2.1 admin 32211   2015-04-04
 
109 OpenSIPS 2.1 (rc) is available, download now! admin 25497   2015-03-22
 
108 Service Provision Using Asterisk & OpenSIPS - AstriCon 2014 admin 34082   2015-02-25
 
107 SIP Signaling-Messages OpenSIPS Running On Multicore Server file admin 42642   2014-11-02
 
106 opensips.cfg for Asterisk admin 37963   2014-10-20
 
105 A2Billing and OpenSIPS config admin 38768   2014-10-20
 
104 Jitsi Videobridge meets WebRTC admin 45784   2014-10-18
 
103 A Survey of Open Source Products for Building a SIP Communication Platform admin 40649   2014-10-18
 
102 Script Function , Module Index v1.11 함수 모듈 opensips admin 36420   2014-10-14
 
101 UAC Registrant Module admin 39968   2014-09-28
 
100 Opensips TM module enables stateful processing of SIP transactions admin 46117   2014-10-04
 
99 kamailio.cfg configuration Example admin 37565   2014-10-04
 
98 opensips NAT Traversal Module admin 37722   2014-10-02
 
97 opensips Nat script with RTPPROXY - English Good perfect admin 37973   2014-08-15
 
96 MediaProxy 2.3.x & OpenSIPS 1.5.x Integration admin 40591   2014-08-24
 
95 RTPPROXY Admin Guide admin 41894   2014-08-24
 
94 CANCEL MESSAGE not handled correctly admin 39671   2014-08-23
 
93 [Sipdroid] SIP data collection study tour admin 39979   2014-08-23
 
92 Many OPENSIPS Configuration Examples This will Help you admin 49721   2014-08-23
 
91 Real-time Charging System for Telecom & ISP environments admin 40838   2014-08-23
 
90 OPENSIPS EBOOK admin 38830   2014-08-21
 
89 Opensips Documentation Function admin 41624   2014-08-21
 
88 Presence Tutorial OpenXCAP setup admin 41295   2014-08-18
 
87 Opensips Modules Documentation admin 42770   2014-08-18
 
86 A lightweight RPC library based on XML and HTTP admin 40796   2014-08-18
 
85 OpenSIPS Control Panel (OCP) Installation Guide Good admin 68825   2014-08-13
 
84 Installation and configuration process record opensips opensips-cp admin 70772   2014-08-13
 
83 OpenSIPS as Homer Capture server admin 37418   2014-08-13