한국어

소프트스위치

온누리070 플레이스토어 다운로드
    acrobits softphone
     온누리 070 카카오 프러스 친구추가온누리 070 카카오 프러스 친구추가친추
     카카오톡 채팅 상담 카카오톡 채팅 상담카톡
    
     라인상담
     라인으로 공유

     페북공유

   ◎위챗 : speedseoul


  
     PAYPAL
     
     PRICE
     

pixel.gif

    before pay call 0088 from app


Gateway between SIP and SMPP messages

phone

While the SIP protocol is one of the most popular protocols used for voice calls, the SMPP (Short Message Peer-to-Peer) is one of the most widely used protocols for sending text messages. Having both of them offered by your service enhances your platform with more compatibility and flexibility.

In order for your customers to have an unified experience, one has to ensure that messages coming from one side are visible and accessible by the other side. For example, someone might send an SMS that comes to your platform over SMPP and it needs to be delivered to a SIP endpoint. Since the two protocols are incompatible (see Compatibility below), there needs to be a tool that does bridging between the two protocols.

Luckily, OpenSIPS 3.0 now features a SIP to SMPP gateway using the new proto_smpp module! This module acts as an ESMEs (External Short Messaging Entity) that is able to connect to a SMSCs (Short Message Service Center) and exchange text messages with it.

Compatibility

Messages in SMPP are binary encoded PDUs (protocol data units) that are carried between the entities involved over TCP. Since it’s using a stream oriented transport protocol, the SMPP protocol has a plethora of commands that are used to keep a SMPP session active and exchange data between endpoints: when starting a SMPP session, an ESME needs to send one of four bind commands (bind_receiver, bind_transmitter, bind_transceiver, or outbind) to the SMSC, depending on its role (receiver, transmitter, or both). Each command has to be confirmed (for example using a bind_receiver_resp acknowledgement for a bind_receiver command). After that, pinging (enquire_link) has to be sent periodically to keep the connection open. Finally, when a text message is sent, a different command command is used, depending on the state of the component.

On the other hand, in SIP things are simpler – messages are constructed using plain text SIP MESSAGE packets (RFC 3428). These messages can be exchanged between SIP endpoints and proxies using any transport protocol supported by SIP (UDP, TCP, TLS, SCTP, WebSocket), the most common one being UDP. Each SIP message sent needs to be confirmed by the receiver using a 200 OK. And that’s it.

Therefore it is clear that the two protocols are not compatible from a behavioral point of view. However, at the end of the day, both protocols are used to transport (mainly) text messages. So as long as we have the actual message payload and meta-data, all we have to do is to building the message according to the transport protocol we need to use.

Configuration

In order to use SMPP connections in your OpenSIPS install, you have to load the proto_smpp module and define a listener that will be used for communication:

listen = smpp:127.0.0.1:2775
...
load_module "proto_smpp.so"

As noted in previous section, for an SMSC to be able to deliver messages to an ESME, all SMPP connections need to be created beforehand. This is done automatically by OpenSIPS at startup. All connections that have to be initiated are described in a database, along with all the parameters they need. So the next thing that has to be configured in the script is a connection to a database:

mysql://opensips:opensipsrw@localhost/opensips

Below you can find an example of a MySQL record that describes an SMPP connection used to connect to an SMSC as a transceiver (session_type=1):

        name: SMPP_test
          ip: 127.0.0.1
        port: 2777
   system_id: smpp
    password: test
 system_type: 
     src_ton: 2
     src_npi: 1
     dst_ton: 2
     dst_npi: 1
session_type: 1
  • name: represents an arbitrary, unique name that will be used to reference this SMPP connection from the script
  • ip and port: the TCP information needed to connect to the SMSC
  • system_id (also known as the user name) and password are used for authentication
  • system_type is a field required by some SMPP providers, and it is usually used to identify the types of services that connection is allowed to use
  • TON (Type of Number) for source (src_ton) and destination (dst_ton) indicate the format of the numbers used for sender and receiver. Some common values are:
    • 0 – Unknown
    • 1 – International
    • 2 – National
    • 3 – Network Specific
    • 4 – Subscriber Number
    • 5 – Alphanumeric
    • 6 – Abbreviated
  • NPI (Number Plan Indicator) for source (src_npi) and destination (dst_npi) represent the numbering scheme used for the clients. Common values are:
    • 0 – Unknown
    • 1 – ISDN/telephone numbering plan (E163/E164)
    • 3 – Data numbering plan (X.121)
    • 4 – Telex numbering plan (F.69)
    • 6 – Land Mobile (E.212)
    • 8 – National numbering plan
    • 9 – Private numbering plan
    • 10 – ERMES numbering plan (ETSI DE/PS 3 01-3)
    • 13 – Internet (IP)
    • 18 – WAP Client Id (to be defined by WAP Forum)
  • session_type is used to specify the type of connection, and has to have one of the following values:
    • 1 – Transceiver
    • 2 – Transmitter
    • 3 – Receiver
    • 4 – Outbind

Once the connection has started, OpenSIPS can use it to exchange messages with its peer. The module will handle in the background all the SMPP protocol’s specifics.

SIP to SMPP gateway

When getting a text message from a SIP entity, it will be handled just like any other SIP request, by running the script. And if according your routing logic that message needs to end up to a SMSC, all you have to do is to call the send_smpp_message() method, specifying which SMSC should be used:

if (is_method("MESSAGE") && isflagset(TO_SMPP_TEST))
    send_smpp_message("SMPP_test");

SMPP to SIP gateway

When a message comes from a SMSC to OpenSIPS over SMPP, things get a bit more complicated – since SMPP messages are binary encoded, they can’t be sent directly to the script. Instead, they are translated to a SIP MESSAGE, and automatically sent to a SIP server or proxy, indicated by the outbound_uri parameter. Usually, the URI points to the same OpenSIPS instance, but note that the message will be sent over SIP – this means that it will be able to enter the script for determining its next hop, or final destination.

listen = udp:127.0.0.1:5060
...
# send all SMPP messages on loopback to the same instance
modparam("proto_smpp", "outbound_uri", "sip:127.0.0.1:5060")
...
route {
    ...
    if (is_method("MESSAGE") && $Ri == "127.0.0.1") {
        # handle message received over SMPP
        ...
    }
    ...
}

And that’s it, you know have a two-way gateway beween SIP and SMPP.

Conclusions

With only a few lines of configuration and the new SMPP module you can easily enhance your OpenSIPS-based VoIP platform with new means of sending text messages. Just give it a try and let us know if you ran into any trouble while setting up this feature!

Special thanks go to Victor Ciurel for developing and testing the new SMPP module in OpenSIPS!

조회 수 :
268749
등록일 :
2019.02.19
22:15:06 (*.214.125.21)
엮인글 :
http://webs.co.kr/index.php?document_srl=3318883&act=trackback&key=29f
게시글 주소 :
http://webs.co.kr/index.php?document_srl=3318883
List of Articles
번호 제목 글쓴이 날짜 조회 수sort
142 Kamailio :: A Quick Introduction admin 2013-04-06 82703
141 Opensips Installation, How to. admin 2014-03-05 76562
140 OpenSIPS configuration for 2 or more FreeSWITCH installs admin 2014-03-12 75611
139 오픈소스 (사내)메신저 서버 구축, 오픈 파이어(openfire) 설치방법과 세팅(리눅스 기준) admin 2017-09-09 73959
138 Opensips1.6 ebook detail configuration and SIP signal and NAT etc file admin 2017-12-10 73925
137 Installation and configuration process record opensips opensips-cp admin 2014-08-13 70719
136 OpenSIPS Control Panel (OCP) Installation Guide Good admin 2014-08-13 68788
135 opensips 1.11.2 install Good Giide admin 2014-08-09 67258
134 ICE: The ultimate way of beating NAT in SIP admin 2014-08-23 65715
133 Build-Depends debian 8.8 opensips 2.3 admin 2017-09-04 65616
132 2013 2012년 분야별 최고의 오픈소스 소프트웨어 124선 admin 2014-04-05 63986
131 Fail2Ban Freeswitch How to secure admin 2017-09-12 62478
130 rtpengine install and config admin 2017-09-05 59553
129 OfficeSIP Server is freeware VoIP, SIP server for Windows admin 2013-09-11 55586
128 Video conference server OpenMCU-ru - Introduction admin 2014-04-01 55252
127 100% CPU usage opensips admin 2014-03-05 55190
126 rtpengine config basic and opensips configuration and command admin 2017-09-06 54558
125 OpenH323 Gatekeeper - The GNU Gatekeeper admin 2011-12-14 54511
124 Kamailio 3.3.x and Asterisk 10.7.0 Realtime Integration using Asterisk Database admin 2013-04-06 53372
123 SIP to XMPP Gateway + SIP Presence Server opensips admin 2017-09-13 53337
122 Using the openSIPS Registrant Module admin 2014-03-09 53000
121 Many OPENSIPS Configuration Examples This will Help you admin 2014-08-23 49670
120 Problem with presence_xml module Opensips 1.9 admin 2014-03-06 48525
119 Using TLS in OpenSIPS v2.2.x configuration admin 2017-09-04 48251
118 OpenSIPS routing logic admin 2017-12-12 48172
117 OpenSIPS Installation Notes admin 2014-08-09 48107
116 Asterisk Installation Asterisk Realtime configuration admin 2013-04-06 46794
115 How to install OpenSIPS on CentOS debian module add xcap admin 2014-03-06 46539
114 the OpenSIPS Project OpenSIP admin 2011-12-14 46529
113 OpenSIPS command line tricks admin 2017-09-13 46156